3.1.5 Set or Read Variables
on Set/Read number of lanes
The total physical number of lanes on your track.
on<cr> Reads the current setting.
on4<cr> Set to 4 lane track
ol Set/Read lane character
Indicates lane 1 in the response to the ra, rg and rp commands.
ol<cr> Reads the current setting.
ol0<cr> Set to ‘A’
ol1<cr> Set to ‘1’
ol2<cr> Set to ‘a’
ol3<cr> Set to ‘A’ (Refer to details for reasoning of this.)
op Set/Read place character
Indicates place in the response to the ra, rg and rp commands.
op<cr> Reads current setting of placement character.
op0<cr> Set to ‘a’
op1<cr> Set to ‘A’
op2<cr> Set to ‘1’
op3<cr> Set to ‘!’
om Set/Read lane mask
Mask off the lane specified until reset with om0,on or power cycle.
om<cr> Reads the current setting.
om3<cr> Mask lane 3
om0<cr> Resets mask to use all lanes
od Set/Read number of decimal places in the result values.
od<cr> Reads current number of decimals
od3<cr> Set to 3 decimals
od4<cr> Set to 4 decimals
od5<cr> Set to 5 decimals
or Set/Read automatic reset delay
Set the delay up to 255 seconds.
or<cr> Reads current setting of reset delay in seconds
or10<cr> Set to 10 seconds
or30<cr> Set to 30 seconds
or0<cr> Auto reset off