3.2.11 ra<cr>:Force end of race, immediately return results, then
reset
ComputerFinish Line
Sends
ra<cr> Force end of race immediately.
Description
Finish Line Computer
Returns
A=0.851c B=0.497b C=0.266a D=9.999<cr><lf>
Description
See Appendix A for a detailed description of the result string.
3.2.12 rg<cr>:Return results when race ends
ComputerFinish Line
Sends
rg<cr> The Finish Line will respond when any of the
Description
following conditions occur:
o A car finishes in each lane
o The auto reset time is reached
o The reset switch is pressed
Finish Line Computer
Returns
A=0.851c B=0.497b C=0.266a D=0.976d<cr><lf>
Description
See Appendix A for a detailed description of the result string.
3.2.13 rl<cr>:Read the finish line photo sensors
ComputerFinish Line
rl<cr>
Finish Line Computer
Returns
0000<cr><lf> Not covered (example for 4 lane track.)
Description
1111<cr><lf> Covered
0 or 1 returned for each lane.
<cr><lf> Carriage return sent when setting a new value.
?<cr><lf> Invalid command.